Why a simple routine pays off
Most Roots Blower breakdowns don't happen suddenly. They start as a slightly lower oil level, a slipping belt, a choked filter or a pressure reading creeping up. A short daily walk-round and a log book catch these early, when the fix is cheap.
Use this checklist alongside your blower manufacturer's manual. Where the manual gives a specific interval, oil grade or quantity, follow the manual.
Safety first
- Switch off, isolate and lock out the power before touching belts, guards, pulleys or covers.
- Wait for the rotors to come to a complete stop.
- Release pressure from the discharge line before opening any connection.
- Let the blower cool down — the casing, discharge pipe and oil can be hot enough to burn.
- Refit every belt guard before restarting.
Use an infrared thermometer for temperature checks rather than touching the casing. Never reach near a belt or pulley while the blower can be started.
The checklist
Print this out or copy it into your log book. Adjust the frequency to your conditions — a blower in a dusty cement plant needs its filter checked far more often than one in a clean pump room.
Daily
- Check oil level in both sight glasses (gear end and drive end)
- Note discharge pressure and compare with your normal reading
- Note motor current (amps) if your panel has an ammeter
- Listen for any change in sound — knocking, rubbing or squealing
- Look for oil leaks around covers, plugs and the shaft
- Record running hours in the log book
Weekly
- Inspect the suction air filter; clean it more often in dusty areas
- Check belts for cracks, glazing or fraying
- Check that the pressure relief valve is not passing air at normal pressure
- Check the blower doesn't spin backwards after stopping (non-return valve)
- Check casing and bearing-end temperature with an infrared thermometer
- Switch duty and standby blowers so both machines run regularly
Monthly
- Check and adjust belt tension; check pulley alignment
- Clean or replace the air filter element
- Check foundation and base frame bolts for tightness
- Check vibration and compare with last month's reading
- Check oil condition — dark, milky or gritty oil should be changed
- Inspect the suction silencer, flexible connector and pipe supports
Yearly
- Full inspection by a trained technician: bearings, timing gears, seals and rotor clearances
- Check and test the pressure relief valve and non-return valve
- Check pressure gauges against a test gauge; replace faulty ones
- Replace belts as a matched set if worn
- Review your log book trends to decide whether an overhaul is due
Oil: level, grade and changes
Oil lubricates the timing gears and bearings. Too little causes rapid wear; too much makes the oil churn, heat up and leak past the seals.
- Check the level with the blower stopped, at the mark on each sight glass — gear end and drive end are usually separate.
- Use only the grade and quantity named in your manual or on the blower's oil plate. Don't mix different oils.
- Change the oil after the initial running-in period given in the manual, then at the recommended interval — or sooner if it looks dark, milky or gritty.
- Milky oil suggests water getting in; metal particles suggest gear or bearing wear. Both need investigating.
- Clean around the oil plug before opening it so dirt doesn't fall in.
Belts and alignment
Belt problems are one of the most common causes of lost airflow and bearing damage.
- Too loose: belts slip, squeal, run hot and the blower runs slower than designed, so airflow drops.
- Too tight: extra load on the drive-end bearing and motor bearing, shortening their life.
- Check pulley alignment with a straight edge across both pulley faces.
- Replace belts as a matched set, never one at a time.
- New belts stretch — recheck tension after the first few days of running.
Air filter and silencer
A choked filter starves the blower, raises temperature and loads the motor. A torn filter lets dust in, which wears the rotors and bearings. Both are avoidable.
- Inspect the filter element weekly and clean or replace it as needed.
- Replace elements that are torn, oily or still clogged after cleaning.
- Never run the blower with the filter removed.
- Keep the area around the suction inlet clean and free of loose material.
Pressure relief valve and non-return valve
- Pressure relief valve (PRV): protects the blower and motor from overpressure. It should stay shut at normal running pressure and lift if pressure rises too high. A PRV that hisses at normal pressure is wasting air; one that is stuck shut gives no protection.
- Non-return valve (NRV): stops air flowing back when the blower stops. If the blower spins backwards after shutdown, the NRV needs attention.
- Never adjust the PRV setting above the blower's rated pressure, and never block or remove it.
Readings worth logging
Numbers on their own mean little; the trend is what matters. Log these readings at the same point in the process each day so you can compare.
- Discharge pressure from the gauge
- Motor current (amps)
- Casing or bearing-end temperature
- Vibration, if you have a meter
- Oil level and condition
- Running hours
A steady rise in pressure, temperature, current or vibration over a few weeks is an early warning. Call us before it turns into a breakdown.
When to bring in a technician