Roots Blower Troubleshooting Guide

Symptom by symptom: what usually causes it, what you can safely check yourself, and when to call a technician.

8 min read

How to use this guide

Find the symptom closest to what you're seeing, work through the likely causes, and do the checks in order — simplest first. Most Roots Blower problems trace back to a small number of things: pressure above rating, oil, belts, the air filter, or the valves on the discharge line.

If a check needs the blower opened up, or the symptom points to bearings, gears or rotors, stop there and call us. Running a damaged air blower almost always makes the repair bigger.

Before you start

  • Isolate and lock out the power before any hands-on check.
  • Wait for the rotors to stop and release pressure from the discharge line.
  • Let hot parts cool down; use an infrared thermometer instead of touching.
  • If you hear metallic knocking or rubbing, stop the blower immediately and don't restart it.

Turning the blower by hand is a useful check, but only with power isolated and locked out. It should turn freely and evenly, with no tight spots.

Symptoms, causes and checks

High vibration

Likely causes
  • Loose foundation or base frame bolts
  • Pulley or coupling misalignment
  • Worn, mismatched or unevenly tensioned belts
  • Worn bearings
  • Dust or process build-up on the rotors
  • Running above the rated discharge pressure
  • Pipe strain from unsupported suction or discharge piping
What to check
  • With power isolated, check and tighten foundation and base frame bolts
  • Check pulley alignment with a straight edge and inspect the belts
  • Compare the discharge gauge reading with the blower's rated pressure
  • Make sure pipes are supported and the flexible connector is not stretched
Call us when
Vibration stays high after these checks, keeps rising week on week, or comes with a knocking sound.

Abnormal noise (knocking, rubbing, rattling or squealing)

Likely causes
  • Rotors touching each other or the casing because of worn timing gears or bearings
  • Low or wrong oil in the gear or bearing end
  • Belt slip (a squeal at start-up or under load)
  • Discharge pressure higher than rated
  • Foreign object drawn in through a damaged air filter
  • Damaged suction silencer or loose guard
What to check
  • Check oil level in both sight glasses with the blower stopped
  • Check belt tension and condition
  • Compare the discharge gauge reading with normal running pressure
  • Inspect the air filter for tears or a missing element
Call us when
You hear metallic knocking or rubbing. Stop the blower straight away and don't restart it — continued running can damage the rotors and casing.

High temperature (casing, discharge air or oil)

Likely causes
  • Discharge pressure too high: choked diffusers, partly closed valve or sticking non-return valve
  • Clogged suction air filter or silencer
  • Oil level too high or too low, or the wrong grade of oil
  • Worn rotor clearances letting hot air recirculate inside the blower
  • Poor ventilation or high room temperature
  • Low cooling water flow on water-cooled blowers
What to check
  • Check the discharge gauge and make sure all line valves are fully open
  • Clean or replace the suction air filter
  • Check oil level and confirm the grade matches the manual
  • Check room ventilation and, on water-cooled models, cooling water flow
Call us when
Temperature stays high with normal pressure and a clean filter, or the paint near the casing is discolouring.

Oil leakage

Likely causes
  • Oil filled above the sight glass mark
  • Worn or hardened oil seals
  • Loose or damaged oil plug, or a worn plug washer
  • Damaged cover gaskets
  • Blocked breather or vent
What to check
  • Check that the oil level is at the mark, not above it
  • Tighten the oil plug and replace the washer if damaged
  • Look for wet patches around the covers and gaskets
  • Clean the breather or vent
Call us when
Oil appears in the discharge air or inside the air chamber — this points to oil seal failure and needs the blower opened up.

Low discharge pressure

Likely causes
  • Leaks in the discharge pipeline, joints or flanges
  • Broken diffusers or reduced water level in the aeration tank
  • Pressure relief valve set too low or passing air
  • Belt slip lowering the blower speed
  • Worn rotor and casing clearances
  • A drain or bypass valve left open
What to check
  • Walk the discharge line and listen for air leaks
  • Check the pressure relief valve for air escaping during normal running
  • Check belt tension
  • Confirm drain and bypass valves are closed
Call us when
Pressure is still low with no leaks and a correctly set relief valve — the blower may need its clearances checked.

Low airflow

Likely causes
  • Clogged suction air filter or silencer
  • Belt slip or wrong pulley size reducing speed
  • Leaks in the discharge piping
  • Pressure relief valve opening or passing
  • Non-return valve partly stuck
  • Worn rotors or casing increasing internal slip
What to check
  • Clean or replace the suction air filter
  • Check belt tension and that the pulleys match the original specification
  • Check the pressure relief valve and non-return valve
  • Check for leaks along the discharge line
Call us when
Airflow is low after the filter, belts and valves check out. We can measure performance and inspect internal clearances.

Motor overloading or tripping

Likely causes
  • Discharge pressure above design: choked diffusers, closed valves, blocked non-return valve or silencer
  • Belts over-tensioned
  • Failing bearings or rotors rubbing
  • Low voltage, unbalanced supply or a lost phase
  • Blower speed or pulley changed from the original selection
What to check
  • Check the discharge gauge and open any closed valves
  • Ask your electrician to check supply voltage and motor current on all three phases
  • With power isolated and locked out, turn the blower by hand — it should rotate freely
  • Check belt tension
Call us when
The blower is stiff to turn by hand, or the motor keeps tripping at normal pressure.

Bearing, gear or rotor failure

Likely causes
  • Oil starvation, wrong oil or contaminated oil
  • Running above rated pressure for long periods
  • Over-tensioned belts loading the drive-end bearing
  • Misalignment between blower and motor
  • Dust entering through a damaged air filter
  • Normal wear after long service without overhaul
What to check
  • Stop the blower and don't restart it
  • Drain a little oil and look for metal particles or a milky colour
  • Note the running hours, pressure readings and any recent changes
  • Take photos of the nameplate and any visible damage
Call us when
Always. Bearing, gear and rotor problems need the blower dismantled, inspected and reset to the right clearances by a trained technician.

Blower not starting

Likely causes
  • No power, tripped breaker or overload relay
  • Starter or control panel fault
  • Rotors jammed by deposits, rust after a long idle period, or rotor contact
  • Starting against a closed discharge valve or high back pressure
  • Broken belts
What to check
  • Ask your electrician to check the supply, breaker, overload relay and starter
  • With power isolated and locked out, try turning the blower by hand
  • Open the discharge valve and check the line is not blocked
  • Check that the belts are in place and intact
Call us when
The rotors won't turn by hand, or they turn with tight spots or grinding.

Blower spins backwards after stopping

Likely causes
  • Non-return valve not closing, letting air flow back from the line or tank
What to check
  • Inspect the non-return valve flap or disc and its seat for dirt or damage
Call us when
The valve is damaged or the problem continues — reverse running can damage the blower and its drive.

Start with the pressure gauge

Because a Roots Blower pushes a fixed volume of air every turn, anything that restricts the discharge — choked diffusers, a part-closed valve, a sticking non-return valve — raises pressure. Higher pressure means more heat, more motor current and more load on bearings and gears. Many 'blower faults' are really system faults downstream, so compare today's gauge reading with your normal one before anything else.

If the gauge itself looks wrong — stuck needle, not returning to zero — replace it. You can't troubleshoot well with a faulty gauge.

What to tell us when you call

The more we know before we arrive, the faster we can fix it and the more likely we are to bring the right parts.

  • Blower make, model and serial number (a nameplate photo is ideal)
  • The symptom, when it started, and whether it's getting worse
  • Current and normal discharge pressure and motor current
  • Any recent work: oil change, new belts, piping changes
  • A short video with sound, if the problem is noise or vibration

Need a hand with your Roots Blower?

Book a technician, order the right spare part, or message us on WhatsApp with a photo of the problem.